Scantronic 8 Zone End Station & 9943 Prox Keypad

Scantronic 8 Zone End Station & 9943 Prox Keypad

EA9651-EN43

This keypad is perfect for wired alarm systems


Please login in to see prices

Only 0 left!

The Scantronic 9651EN is a fully programmable, 8 zone security alarm panel designed to conform to PD6662:2004 Grade 2X system requirements.

The 9651EN is ideally suited to both home and small commercial security applications, combining maximum flexibility with ease of use to provide optimum security when and where you need it.

Simple A, B, C and D setting buttons let you to split the system into four areas, enabling you to set the whole, or just parts of the alarm protection.

Up to 4 attractive remote keypads can be added to any system. The 9943 keypad supplied (as pictured) uses a 4 or 6-digit PIN code to control system operation and the ability to use PROX fobs to set/unset the system.

A 9651 panel can be connected to any speech dialler or plug-by digital communicator via its integral communications output socket. Its three fully programmable outputs further enhance system flexibility. A 700 event log, fully date and time stamped to comply with the Association of British Insurers requirements, provides a complete record of system operation and service information.

Specifications

General

 
Product name 9651EN
Security Grade EN50131-1 or PD6662 Grade 2x
Sales number 09651EN-43
   

Capacities

 
Max zones 8
Zones - on board 8 FSL or 8CC (with common tamper)
Zones - on expander None
Standard wired outputs 3
Communicator outputs: 8
Setting Levels: 1 Full + 3  Part (one partition)
Partitions: Four (no part setting partitions)
Log capacity (events): 700
No. Keypads 4
Internal Clock ±10 minutes over one year (depending on the accuracy of the mains supply frequency).
Downloader None
   

Security

 
Access code  4 or 6 digits
Number of user codes 50 plus installer
Code blocking Blocked for 90s after 13 incorrect characters in series.
Proximity tag differs 4,294,967,296
   
Physical  
End Station  
End Station dimensions: 235mm W, 245mm H, 90mm D
End Station weight (w/o battery): 3.3 kg
Case material Steel
   

Keypad

 
Keypad name 9941/9943
   

Environmental

 
Environmental Grade Class II
Operating temperature -10° to +55°C
Humidity 96% RH
   

Radio

 
Expander/Built-in: None
   
Communications  
Built in Communicator No
Plug on communicator No
Plug-by communicator Provides 8 programmable outputs for plug-by module.
Protocols: Depends on communicator
   

Power Supply

 
EN50131-6 Type  
Mains power supply 230VAC +10%/-15%, 200mA max, 50/60Hz ±5%
End station psu 13.8VDC, 1.0A
End station consumption 130mA quiescent, 220mA active
Keypad consumption (Backlight  OFF) 30mA
Keypad consumption (Backlight ON) 70mA
Standby Battery 12V rechargeable lead-acid, gel-type battery.
Low battery voltage cutoff: 10V
Standby time:  Depends on battery
Max recharge time: Depends on battery
Battery charge limit 250mA
12V Aux supply (inc LS) 12VDC min, 13.8VDC max,  ripple ±2% maximum, 500mA,.
14V4 supply None
Monitoring includes Mains fail, battery low voltage, battery failure.
   

Outputs

 
O/P 1 Open-collector transistor outputs, 500mA, 12VDC, negative applied.
O/P 2 Open-collector transistor outputs, 500mA, 12VDC, negative applied.
O/P 3 Open-collector transistor outputs, 500mA, 12VDC, negative applied.
O/P 4 None
O/P 5-8 None
LS (loudspeaker) Supports two parallel-connected, externally mounted loudspeakers for internal sounder or EE tones: minimum speaker impedance 8Ω.
Communication outputs 12V logic outputs, negative applied in alarm (positive removed), 50mA maximum.
ST (Siren test) None
   

Inputs

 
TR Tamper return for Bell
Tellback/Remote reset** Tellback/Remote reset**. +12V applied to operate reset.
Line Fault input** Line Fault input**. +12V applied to indicate line failure.
   

Fuses

 
Mains The panel uses a T-250mA mains fuse.
Other The panel uses fast-acting polyswitch fuses for overcurrent protection:
  F1 – 12V AUX output
  F2 – Battery output
  F3 – Bus 1